Flexible Hoses
FLANGE TYPE
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F110 | ![]() |
FLANGE END | LAPPED FLANGE |
15A to 100A |
1.0MPa | 350ºC |
|
| F115 | ![]() |
NON WELDING TYPE PUMP CONNECTOR | FLANGE | 20A to 300A |
1.0MPa of above *1 |
300ºC *5 |
|
| F118 | ![]() |
NON WELDING TYPE PUMP CONNECTOR | FLANGE | 20A to 50A |
1.0MPa | 350ºC |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F120 | ![]() |
FLANGE END | LAPPED OR FIXED FLANGE THREADS | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F130 | ![]() |
FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS10K) |
32A to 300A |
1.4MPa | 20ºC *4 |
|
| F135 | ![]() |
FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS20K) |
32A to 200A |
2.8MPa | 20ºC *4 |
|
| F138 | ![]() |
FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS10K) |
32A to 50A |
1.4MPa | 20ºC *4 |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F140 | ![]() |
OFFICIALLY CERTIFIED FLEXIBLE JOINT (JAPAN) | LAPPED OR FIXED FLANGE | 40A to 350A |
1.0MPa | 100ºC *4 |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F150 | ![]() |
FLANGE END LAYING UNDER THE GROUND TYPE | LAPPED OR FIXED FLANGE | 10A to 350A |
1.0MPa of above *1 |
80ºC |
|
| F155 (SEMI) |
![]() |
SEMI-JACKET TYPE | LAPPED OR FIXED FLANGE THREADS | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
| F155 (FULL) |
![]() |
FOR COOLANT PIPING | FIXED FLANGE | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| F165 | ![]() |
FOR COOLANT PIPING | LAPPED OR FIXED FLANGE THREADS | 15A to 200A |
1.0MPa of above *1 |
-196ºC to 80ºC |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| T670 | ![]() |
FLUORO- PLASTIC LINED TUBES |
LAPPED OR FIXED FLANGE | 15A to 350A |
*1 | 270ºC *3 |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| B710 | ![]() |
NON WELDING TYPE PUMP CONNECTOR | FLANGE | 50A to 300A |
1.0MPa | - |
|
| B720 | ![]() |
NON WELDING TYPE PUMP CONNECTOR | FLANGE | 50A to 300A |
2.0MPa | - |
|
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| E410 | ![]() |
BELLOWS TYPE EXPANSION JOINT | FIXED FLANGE |
20A to 200A |
1.0MPa | 220ºC *4 |
|
| E420 | ![]() |
BELLOWS TYPE EXPANSION JOINT | FIXED FLANGE |
20A to 200A |
1.0MPa | 220ºC *4 |
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing.
THREADS TYPE
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| S210 | ![]() |
NON WELDING TYPE FEMALE UNIONS END | FEMALE THREADS | 15A to 50A |
1.0MPa | 100ºC |
|
| S215 | ![]() |
NON WELDING TYPE CONNECTION BETTWEEN NUT AND TUBES | MALE OR FEMALE THREADS | 8A to 25A |
1.0MPa of above *1 |
100ºC |
|
| S220 | ![]() |
FEMALE UNIONS END | FEMALE THREADS | 8A to 100A |
1.0MPa of above *1 |
350ºC *3 *5 |
|
| S221 | ![]() |
CORE UNIONS END | FEMALE THREADS | 15A to 50A |
1.0MPa | *2 |
|
| S222 | ![]() |
FEMALE UNIONS END | FEMALE THREADS | 6A to 100A |
1.0MPa of above *1 |
350ºC *3 |
|
| S225 | ![]() |
SWIVEL COUPLING WITH METAL TO METAL SEAL | MALE OR FEMALE THREADS | 6A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
| S227 | ![]() |
FEMALE SWIVEL END | FEMALE THREADS | 8A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
| S228 | ![]() |
SWIVEL COUPLING WITH METAL TO METAL SEAL | MALE OR FEMALE THREADS | 6A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
| S230 | ![]() |
THREADED END | MALE OR FEMALE THREADS | 6A to 100A |
1.0MPa of above *1 |
350ºC *3 |
|
| S270 | ![]() |
TANKER JOINT | THREADS | - | 1.0MPa of above *1 |
350ºC *3 |
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing
COUPLING TYPE
| TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
| C310 | ![]() |
CAM-LOCK END | CAM-LOCK | 15A to 150A |
1.0MPa of above *2 |
*5 |
|
| C315 | ![]() |
QUICK COUPLING | QUICK COUPLING | 8A to 50A |
1.0MPa of above *2 |
*5 |
|
| C320 | ![]() |
PIPE END | STEEL PIPE OR COPPER PIPE | 6A to 350A |
1.0MPa of above *1 |
*3 |
|
| C325 | ![]() |
COUPLING CONNECTION | COUPLING CONNECTION | 25A to 50A |
- | 80ºC *3 |
|
| C330 | ![]() |
COPPER SOCKET END | COPPER SOCKET | 8A to 80A |
1.0MPa of above *1 |
*3 |
|
| C340 | ![]() |
SANITARY FITTINGS END | FLANGE OR THREADS | 6A to 200A |
1.0MPa of above *1 |
*5 |
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing.


































